8051 timing counting online calculator

Release time : 2019-12-17 02:34:01 UTC      

Category : Daily

Page Views: 56 views

Megahertz (mhz)
Milliseconds (mSec)
Timed taskStandard 12 time periodEnhanced 6 clock cyclesTime
Single timer
1 / (mhz/12)

1 / (mhz/6)
uSec
8 bit timing counter
TIC12 * 256 / 1000

TIC6 * 256 / 1000
mSec
16 bit timing counter
TIC12 * 65536 / 1000

TIC6 * 65536 / 1000
mSec
8 digit recalculation value
256 - (DRT / TIC12 * 1000)

256 - (DRT / TIC6 * 1000)
mSec
16 bit recalculation value
65536 - (DRT / TIC12 * 1000)

65536 - (DRT / TIC6 * 1000)
mSec

App description

Mode 0 is the 13-bit timer counting mode, mode 1 is the 16-bit timer counting mode (which is the most common mode), mode 2 is the 8-bit automatic reloading initial value counting mode, mode 3 is only applicable to T0, and 16-bit T0 is divided into Two 8-bit timer counters.