EIA calculation: Estimation of waste gas volume in cement shaft kiln
Calculation formula:
\(Q year = M \times Qa \times K1 \times K2\)
In the formula:
Q year - the annual exhaust gas emissions from the vertical kiln, m3 (standard) / y;
M- shaft kiln clinker annual output, kg/y;
Qa—the amount of waste gas generated per unit clinker, m3 (standard) / kg (clinker), generally 1.6~2.0m3 (standard) / kg (clinker);
K1—production unevenness coefficient, machine shaft kiln K1=1.0, ordinary shaft kiln K1=1.3~1.5;
K2—air leakage coefficient, machine shaft kiln K2=1.15~1.25, common shaft kiln K2=1.3~1.4.