Online calculation tool for boiler flue gas sulfur dioxide (SO 2 ) emission

Category: EIA


EIA calculation: boiler flue gas calculation

1 Kg coal produces 8.5 m3 flue gas (experience); 1 Kg coal in chain furnace produces 10.35 m3 flue gas;

Source strength calculation formula:

QSO2:\(Q=G×2×0.8×S×(1-ηS)\);

In the formula:

G-calcium consumption, mg/s;

S-sulphur content in coal;

ηS-desulfurization efficiency, %, grit water bath, water film is 40%, limestone-gypsum method is 90%.